KJ-A3

  • Detail
  • Parameters
Overview:Air Purification and Disinfection Terminal
Dimensions:490 × 244 × 729 mm
Applicable Area:56–95 m²
Air Volume:720 m³/h
CADR:700 m³/h
Wattage:100 W
Noise Level:≤60 dB
Weight:15.6 kg
Voltage:100-250V~
Frequency:50-60Hz
Running time:≥ 30 minutes
Plasma density:2.16×10¹⁶/m³
Air natural bacteria sterilization rate:99%
Staphylococcus albus sterilization rate:99.99%
Ozone residue:≤0.002 mg/m³

KJ-A3 Plasma Air Purifier: The Invisible Shield for Hospital Cross-Infection Prevention

In the bustling corridors of hospitals, every breath carries hidden risks—pathogens from coughing patients, formaldehyde from medical supplies, and ozone from sterilization equipment. Hospital public areas, with 5,000+ daily visitors, are prime cross-infection zones where air pollution isn’t just a health issue but a silent spreader of diseases. The plasma air purifier, leveraging 6th-generation medical-grade technology, emerges as the ultimate solution to transform these spaces into fortified zones of clean, safe air.

I. Hospital Public Areas: The Unseen Cross-Infection Hotspots

  • Biological Contamination Matrix
    • Waiting areas harbor 1,800 CFU/m³ of bacteria (5x mall levels), including MRSA and E. coli.

    • Elevator buttons carry 10x more microbes than toilet seats, creating "touch-to-air" contamination chains.

  • Chemical Pollution Risks
    • Chlorine disinfectant VOCs mix with medical plastic formaldehyde, often exceeding 0.08mg/m³ by 1.5x.

    • UV disinfection lamps generate ozone (O₃> 0.1ppm), irritating 医护人员呼吸道 and increasing occupational risks.

  • Physical Pollution Cycles
    • Patient-carried PM2.5 and droplet nuclei circulate in central air systems, forming "pollution loops."

    • Fabric chairs and carpets adsorb germs, releasing them continuously into the air.

II. Plasma Technology: Redefining Hospital Air Safety

1. Active Sterilization: The Nanoscale Pathogen Hunter


  • Ion clusters penetrate bacterial biofilms and viral envelopes, achieving 99.99% inactivation of influenza H1N1 (CDC-certified).

  • A tertiary hospital saw pediatric ward cross-infection rates drop by 76% after plasma installation.


2. Decompositional Purification: Dual Chemical Threat Terminator


  • Plasma catalysis breaks formaldehyde into H₂O + CO₂, stabilizing levels at 0.03mg/m³ in emergency rooms.

  • Activated carbon-composite filters, combined with plasma fields, eliminate 98% of medical waste odors (ammonia, 血腥味), improving staff working environments.


3. Medical-Grade Ventilation: Oxygenation & Pollution Control


  • HEPA-H14 filters (99.995% @ 0.3μm) ensure incoming air meets OR standards, blocking PM2.5-borne pathogens.

  • 6x/hour air replacement in waiting areas reduces CO₂ to 800ppm, minimizing patient dizziness.


4. Silent & Safe Coexistence


  • Operates at ≤25dB (quieter than nurse station chatter), with O₃ < 0.01ppm—compliant with GB15982-2021 Hospital Disinfection Standards.

  • 24/7 operation eliminates the need for shutdown sterilization, maintaining continuous protection.

III. Scene-Specific Infection Control Solutions

  • Emergency Waiting Areas
    "Emergency Sterilization Mode" inactivates COVID-19 within 3 minutes (lab data: 99.9% coronavirus kill rate), filtering cough-generated aerosols to protect 医护人员.
  • Elevator Cabs
    Embedded plasma modules cycle air every 15 seconds, reducing elevator flu virus detection from 68% to 3%, and surface bacteria by 95%.
  • Corridors & Stairwells
    Ceiling-mounted systems with AI sensors boost purification power during peak 人流,reducing corridor PM2.5 from 58μg/m³ to 8μg/m³.
  • Restrooms
    "Bacteriostasis Mode" kills 99.9% of toilet-area E. coli in 10 minutes, while decomposing ammonia to reduce odor intensity from "strong" to "faint".

IV. Hospital Purification Technology Comparison

TechnologyUV DisinfectionElectrostatic PrecipitatorPlasma Technology
Sterilization MechanismSurface irradiationElectric field (ozone risk)Active ion diffusion, 360° coverage
Cross-Infection Reduction<30% (direct exposure needed)45–50%72–89% (clinical data-supported)
Human-Machine SafetyUV damages eyes/skinOzone 超标风险No radiation/ozone, 24-hour safe coexistence
Maintenance CostQuarterly lamp replacementMonthly electrode cleaning24-month filter life, 70% lower maintenance

V. Breathe Safe, Heal Better

"In hospitals, clean air is not a luxury but a critical defense." Plasma air purifiers don’t just purify—they construct invisible barriers against cross-infection, protecting both patients and healthcare heroes. By neutralizing pathogens, decomposing toxins, and enriching oxygen, they transform bustling public areas into sanctuaries of health. After all, the first step to healing starts with a breath that carries hope, not harm.


型号
KJ-A3
品牌
康蓓净
Home
Customer service
立即预约